SEL-735

SEL-735

Power Quality and Revenue Meter

The SEL-735 offers high-accuracy metering combined with detailed power quality analysis. With data available at their fingertips, operators can easily identify power system anomalies and mitigate their impact. For high-accuracy revenue metering applications, the SEL-735 exceeds ANSI C12.20 0.1 and IEC 62053-22 0.1 S accuracy class requirements over a wide current range. The SEL-735 maintains this accuracy through its entire service life, eliminating costs associated with field calibration. This makes the SEL-735 the premier choice for points of common coupling, interchanges, and critical loads. With optional continuous waveform streaming, the SEL-735 precisely samples and sends waveform data from the power system at 3 kilosamples per second (ksps). Accessories and Mounting OptionsView Ship-From-Stock Meters

Starting at

$2,260

Ensure Accurate Revenue Metering

Exceed Accuracy Class 0.1 requirements with bidirectional, full four-quadrant energy metering. The SEL-735 remains accurate over its entire life without requiring recalibration and provides precise measurements even in the presence of distorted waveforms.

Capture Power Quality Disturbances

The SEL-735 measures harmonics, interharmonics, flicker, power factor, voltage disturbances, K-factor, and other key power quality indicators with full conformance to IEC 61000-4-30 Class A requirements.

Record Long-Term Trends

The load profile recorder captures years of data with simultaneous meter and power quality logging of up to 512 analog channels for up to 20 years. The SEL-735 can trend averages, minimums, maximums, changes, and snapshots at a rate as often as every three seconds.

Stream and Record Waveform Data

The SEL-735 captures every disturbance in your power system. Optional continuous waveform streaming precisely samples voltage and current signals at 3 ksps and sends the data to SEL Synchrowave software for visualization.

Record Voltage Sag, Swell, and Interruption (VSSI) Data

The VSSI recorder time-stamps voltage excursions with up to 4 ms resolution and records indefinitely using an adaptive sampling rate.

Streamline Commissioning and Testing

View real-time metered quantities, phasor diagrams, voltage and current waveforms, and more with the intuitive touchscreen display. Speed up accuracy testing by visualizing test pulses, accumulated energy, and instantaneous signals.

Bundle Hardware and Software

Automate data retrieval, quickly visualize data, and create custom reports with the enterprise data collection and reporting software bundle, which includes Synchrowave Reports software. View software bundling options here.

Updates

Latest enhancements: continuous waveform streaming

The SEL-735 can now continuously stream waveform data at 3 ksps to SEL-5703 Synchrowave monitoring. Contact us for more information.

Minimize the cost of harmonic mitigation with continuous waveform recording

David Renfro from Infiniti Integration Services describes SEL continuous waveform recording as the arbiter of truth and as a method for capturing all disturbances without custom event trigger logic. Learn how he optimizes filter designs for harmonics caused by variable-speed motor drives.

Continuous waveform streaming system

SEL-735 Features

735_LDM_Front_Home.png
1
2
3
4
5
6
7
  1. Capacitive 5-inch (12.7 cm) color touchscreen
  2. Continuous monitoring for all three power system phases; customizable screens that provide useful defaults, large fonts, and numerous choices for analog quantities
  3. Folders and applications to access information
  4. Six programmable LEDs
  5. USB Type-C port
  6. Simple Test Mode access
  7. Customizable local controls
735_LCD_Front.png
1
2
3
4
5
6
7
  1. Customizable three-line or single-line display
  2. Customizable scaling and formatting
  3. Simple front-panel navigation
  4. Six programmable LEDs
  5. Customized local controls
  6. ANSI Type II optical port or EIA-232 port
  7. Custom nameplate and barcode
735_LDM_Back.png
1
2
3
4
5
6
  1. Power supply board: 2 inputs, 3 outputs
  2. Main board: RJ45 copper or fiber-optic Ethernet, EIA-232, IRIG-B, EIA-232/-485
  3. Communications board: EIA-485, telephone modem, EIA-232
  4. Sealing provision
  5. I/O board: 4 inputs, 4 outputs (solid-state or electromechanical); or 4 analog outputs, 4 solid-state outputs
  6. CT and PT inputs board
Wave View with Vb Figure 3.11.png
1
2
  1. View cycle-by-cycle voltage and current waveforms in real time.
  2. The Wave View feature provides oscilloscope-like visibility to help you identify system distortions and troubleshoot power quality issues that affect sensitive equipment.
Phasors_Figure_3.7.png
1
2
  1. Analyze the real-time voltages and currents in a power system during balanced and unbalanced conditions.
  2. Use phasor data to verify correct system wiring during commissioning and identify changes as loads vary.
Energy Metering Figure 3.15.png
1
2
  1. View energy metering quantities imported and exported by the system.
  2. Reset energy values via the display, and record the time and date of reset.
Test Mode Energy Figure 10.8.png
1
2
  1. Speed up accuracy testing by visualizing test pulses, accumulated energy, and instantaneous signals.
  2. When in Test Mode, the SEL-735 freezes the billing quantities to isolate your test inputs from revenue billing.
735_Portable_PQM_003-mod-LDM.jpg
1
2
  1. Monitor power quality anywhere with the rugged SEL-735. The portable meter logs years worth of data with 1 GB of onboard memory.
  2. Clamp-on CTs and clip-on voltage leads detect current and voltage disturbances.
734_EXM-4.jpg
1
2
  1. The easily extractable meter uses simple retrofit brackets to replace draw-out meters.
  2. For field testing, pull the quick-release latches and remove the disconnects to extract the meter.
735_in_PlastHousing_Open_mask.jpg
1
2
  1. Replace socket meters with a low-cost enclosure and prewired FT-1 test switch.
  2. Install the meter quickly due to design features including DIN rails for accessories, a lockable stainless-steel latching system, wall-mount brackets, and wire clamps. The fully sealed enclosure complies with NEMA 4X and IEC 60529 Type IP66 ingress protection requirements.

SEL-735 Details

Accurate Metering
The SEL-735 exceeds the requirements of ANSI and IEC accuracy standards over a wide current range. Capable of reliable and precise metering even in the presence of harmonics, the SEL-735 exceeds the Accuracy Class 0.1 requirements of ANSI C12.20 and 0.1 S accuracy class for IEC 62053-22. Quality-focused manufacturing ensures that the meter will meet these accuracy requirements throughout its service life.
Load Profile Data Collection
You can collect billing data with a simple-to-use load profile recorder that captures years of data.
Advanced Integration
The SEL-735 integrates seamlessly into Itron MV-90 billing software, IEC 61850, DNP3, IEEE C37.118, Modbus, or SEL communications architectures. Multiple communications ports and protocols enable the SEL-735 to simultaneously communicate with up to ten devices.
IEEE C37.118.1a-2014 Synchrophasors
Collect real-time measurements of electrical quantities, then use these data to perform wide-area control, validate system models, determine stability margins, maximize stable system loading, detect islanding, record system-wide disturbances, and visualize dynamic system responses. The synchrophasors in the SEL-735 adhere to IEEE C37.118.1a-2014, making them ideal for applications requiring fast response times under dynamic conditions.
Instrument Transformer Compensation
The SEL-735 is the only SEL product to provide both angular and magnitude compensation for instrument transformer errors. Correct delays and errors on each phase to achieve high-performance system accuracy, even when using protection-grade transformers. The SEL-735 is equipped with the powerful combination of IEEE C37.118 and Instrument Transformer Compensation (ITC), so you can choose to apply correction at either the synchrophasor interface or all metering interfaces, providing flexibility for many applications.
IEC 61850 GOOSE and MMS
Using IEC 61850 GOOSE, the SEL-735 can communicate peer to peer with another device to exchange metering, power quality, or control data in real time over Ethernet. Or, it can use MMS to report to an MMS client, such as a SCADA master.
Transformer and Line-Loss Compensation
By entering transformer nameplate and line impedance information directly into the meter, you can automatically compensate for transformer or line losses and move the billing point.
Time-of-Use (TOU) Metering
You can report flexible, time-differentiated energy and demand registers with multiple day types, rates, and seasons as well as a 20-year programmable calendar.
Predictive Demand
With the predictive demand function, you can monitor accumulated demand and alarm when the demand exceeds a user-defined limit. The SEL-735 can then shut down loads or peak-shave with generation to avoid demand charges. The predictive demand alarm is available through IEC 61850, Modbus, DNP3, Mirrored Bits communications, and the front-panel LEDs.
Software Integration Solutions
  • Configure Meters—acSELerator QuickSet SEL-5030 Software is an easy-to-use yet powerful tool with template design capabilities for easy, consistent settings and applications to help you get the most out of your SEL meter. Download QuickSet now.
  • Access Metering Data Conveniently—SEL-5703 Synchrowave Monitoring provides real-time and historic trending and archiving from events captured by the SEL-735. Synchrowave Reports lets you visualize high-resolution power system data and generate reports.
  • Analyze Event Data—SEL-5601-2 synchroWAVe Event Software displays SEL relay event reports and COMTRADE files, allowing you to easily analyze and diagnose relay behavior during a power system fault.
  • Take Action on Metering Data—Synchrowave Reports software visualizes the metering data collected and stored by SEL data retrieval software. With Synchrowave Reports, you can quickly analyze data, identify usage trends, and diagnose system problems.
  • Integrate Data Reporting—Representational state transfer (REST) application programming interfaces (APIs) integrate with enterprise-level systems, such as energy management systems and billing systems. Contact SEL for more details.
Power Quality and Recording Options
Choose from three power quality options to fit any application and budget. Click here to view option descriptions.
Continuous Waveform Streaming to Synchrowave at 3 ksps
Precisely samples voltage and current signals at 3 kilosamples per second (ksps) and sends to SEL Synchrowave software for data visualization.
Displays
Customizable three-line or single-line display 5-inch color touchscreen display, 800 × 480 pixels
Physical Chassis
Panel mount: horizontal or vertical with ANSI optical port or EIA-232 port Easily Extractable Meter (EXM): vertical panel mount with ANSI optical port or EIA-232 port
Enclosure
16" x 18" NEMA 4 enclosure, wired to FT-1 test switch Portable case with voltage clips Front-panel sealing cover
Meter Form
Form 5, Form 36, or Form 9
Power Supply
12/24 Vdc, 24/48 Vdc, or 125/250 Vdc or Vac
Input Voltage (Vdc or Vac; includes 3 contact outputs and 2 inputs)
24, 48, 110, 125, 220, or 250
Communications
EIA-232 and EIA-485
USB Type-C
Ethernet: 10/100BASE-T, 100BASE-FX fiber-optic (available in multimode)
Communications Protocols
IEC 61850 with GOOSE and MMS
Enterprise Data Collection and Reporting Software Bundle
Bundle includes a one-unit license for:
For assistance, visit the SEL Software Licensing Information webpage or contact your local customer sales representative.Conformal-Coated Circuit Boards Flexible Mounting Options
A variety of bezels, brackets, enclosures, and rack-mount kits are available for quick, easy, and clean-looking retrofit installations and mounting flexibility. The SEL Metering Accessories Catalog offers a complete list of accessories. To view all the mounting options, visit the Mounting Selector webpage.

735#T5VF

Price: $2,432.29

Basic Power Quality (PQ) Metering Features

  • 128 MB of recording memory
  • 16 channels of energy and PQ trending
  • 16 samples-per-cycle waveform capture
  • 15th-order harmonic metering
  • 270 VSSI summary events
  • EIA-232 Includes Port 2 EIA-232 Standard (Slot B)

View available ship-from-stock units

    View configuration

    735#0102

    Price: $2,538.34

    Basic Power Quality (PQ) Metering Features

    • 128 MB of recording memory
    • 16 channels of energy and PQ trending
    • 16 samples-per-cycle waveform capture
    • 15th-order harmonic metering
    • 270 VSSI summary events
    • EIA-485 Includes Port 2 EIA-232 Standard (Slot B)

    View available ship-from-stock units

      View configuration

      735#C2L4

      Price: $3,347.89

      Intermediate PQ Metering Features

      • 256 MB of recording memory
      • 192 channels of energy and PQ trending
      • 128 samples-per-cycle waveform capture
      • 63rd-order harmonic metering
      • Flicker measurement
      • IEC 61850

      View available ship-from-stock units

        View configuration

        735#1VT4

        Price: $4,137.49

        Advanced PQ Metering Features

        • 1 GB of recording memory
        • 512 channels of energy and PQ trending
        • 512 samples-per-cycle waveform capture
        • 600 VSSI summary events
        • Wave View
        • Power harmonics
        • Interharmonics
        • Vertical Panel Mount With EIA-232 Port

        View available ship-from-stock units

          View configuration

          735#PQG2

          Price: $4,137.49

          Advanced PQ Metering Enhancements From Intermediate

          • 1 GB of recording memory
          • 512 channels of energy and PQ trending
          • 512 samples-per-cycle waveform capture
          • 600 VSSI summary events
          • Wave View
          • Power harmonics
          • Interharmonics
          • Horizontal Panel Mount With EIA-232 Port

          View available ship-from-stock units

            View configuration

            735#0401

            Price: $5,814.34

            Advanced PQ Metering With Touchscreen

            Enhancements from Advanced Monochromatic Meter:

            • 5-inch color touchscreen display
            • Front USB-C port
            • Enterprise data collection and reporting bundle

            View available ship-from-stock units

              View configuration

              735#A95D

              Price: $8,315.44

              Advanced PQ Metering With Touchscreen and Portable Case

              • Portable package for convenient PQ monitoring
              • 5-inch color touchscreen display
              • Front USB-C port
              • Enterprise data collection and reporting bundle
              • Continuous waveform streaming at 3 kilosamples per second (ksps)

              View available ship-from-stock units

                View configuration

                Configuration

                acSELerator QuickSet SEL-5030 Software

                QuickSet is a tool for engineers and technicians to quickly and easily configure, commission, and manage power system devices. QuickSet includes a Graphical Logic Editor and a device template tool to reduce configuration time and streamline deployment.Learn more and download on the QuickSet software page.

                acSELerator Architect SEL-5032 Software

                Architect allows users to configure and document IEC 61850 systems that include GOOSE, Sampled Values (SV), or Manufacturing Message Specification (MMS) communications. Architect automatically compares SCL files with IEC 61850 requirements to ensure standard compliance.Learn more and download on the Architect software page.

                Automated Data Collection

                SEL Data Management and Automation (DMA) Application Suite

                Available on the Blueframe platform, DMA applications automatically collect, store, and manage device-specific information like oscillography, Sequence of Events (SOE) data, device settings, and property information. They also provide automated password rotation and streamlined device audits.Learn more on the DMA software page.

                Visualization and Analysis

                SEL-5601-2 synchroWAVe Event Software

                Synchrowave Event is an easy-to-use event report analytic software that helps engineers diagnose the cause of power system disturbances, including faults.Learn more and download on the synchroWAVe Event software page.

                SEL-5705 Synchrowave Reports

                Synchrowave Reports automates reporting of metering and power quality data via email or web browser. Quickly identify trends, harmonic disturbances, and other power quality concerns to drive planning, operating, and accounting decisions that will increase efficiency and reduce costs.Learn more and download on the Sychrowave Reports software page.
                The table below indicates the software and features included in the Meter Data, Power Quality, and Energy and Power Monitoring ordering options.
                 Meter Data OptionPower Quality OptionEnergy and Power Monitoring Option
                acSELerator Team1   
                Event and SER collection
                LDP and VSSI collection
                1Both Meter Data and Power Quality options are available without a Team license if an application already has Team software available.
                Synchrowave ReportsMeter Data ReportsPower Quality ReportsPower Quality Reports
                Device Overview
                SER
                LDP
                VSSI
                Signals or WAGES
                IEEE 519 Compliance Report 

                Synchrowave MonitoringTrending and Archiving PackagePower Monitoring Package
                Phasor Measurement Unit (PMU)
                Continuous Waveform Receiving
                Time-Series Historian
                Calculations
                Software PMU
                Virtual Metering
                Visualization
                Data Export
                Notifications/Alarms 
                Oscillation Detection 
                Disturbance Detection 
                PT Failure Detection 
                Threshold Monitoring 
                SEL-734 and SEL-735 Product Feature ComparisonThe SEL-734 Revenue Meter is no longer in production. SEL recommends selecting the SEL-735 in place of the SEL-734.SEL-735 Power Quality and Recording OptionsChoose from three power quality options to fit any application and budget.
                FeatureBasicIntermediateAdvanced
                General
                DisplayCustomizable three-line or single-line displayCustomizable three-line or single-line displayCustomizable three-line or single-line display; 5-inch 800 × 480 color touchscreen display*
                Front PortANSI Type II optical port or EIA-232 portANSI Type II optical port or EIA-232 portANSI Type II optical port or EIA-232 port; Type-C USB*
                Memory128 MB256 MB1 GB
                Max Harmonic Order15th63rd63rd
                Interharmonic QuantitiesNoNoYes
                Harmonic AnglesNoNoYes
                Power HarmonicsNoNoYes
                Waveform Capture
                Samples Per Cycle1616, 12816, 128, 512
                Duration (cycles)1515–60015–600
                Number of Events25633–6,200101–10,000
                COMTRADE ReportsYesYesYes
                Wave View OscillographyNoNoYes
                Continuous Waveform Streaming to SynchrowaveUpgradableYesYes
                Load Profile Data
                Recorders × Channels1 × 1612 × 1632 × 16
                Acquisition Rates1–120 min3–59 s, 1–120 min3–59 s, 1–120 min
                Storage Duration0–10 years, varies with acquisition rate and number of channels used0–20 years, varies with acquisition rate and number of channels used0–20 years, varies with acquisition rate and number of channels used
                Example Duration10 years for 16 channels logged every 10 min20 years for 16 channels logged every 10 min20 years for 16 channels logged every 10 min
                Voltage Sag, Swell, Interruption (VSSI) Recorder
                Typical Number of Summary Events270270600
                Number of Detailed Rows60,00060,000>130,000
                Minimum Disturbance Duration1/4 cycle1/4 cycle1/4 cycle
                Sampling Rate4 samples/cycle–1 sample/day, adaptive4 samples/cycle–1 sample/day, adaptive4 samples/cycle–1 sample/day, adaptive
                Sequential Events Recorder (SER)
                Number of Events>80,000>80,000>80,000
                Number of Channels Monitored≤72≤72≤72
                IEC 61000-4-30 PQ Compliance
                150/180-Cycle, 10-Minute, 2-Hour-Class AClass A
                Flicker-Class A (10-min, 2-hr updates)Class A (1-min, 10-min, 2-hr updates)
                Voltage Harmonics--Class A
                Current Harmonics--Class A
                *Optional feature

                How a Data Center Achieves Utility-Grade Metering

                Reducing Consumption to Serve the Community

                Minimize the cost of harmonic mitigation with continuous waveform recording

                Power Quality Theory

                Metering Theory and Fundamentals

                1 of 2
                • Power Quality Theory

                • SEL-735 Power Quality and Revenue Meter—Transformer and Line-Loss Compensation

                SEL-735: Change Phase Rotation

                How-to Commission the SEL-735 Meter

                1 of 7
                • SEL-735: Change Phase Rotation

                • SEL-735: Form 5 Accuracy Testing

                • SEL-735: Meter Form Change

                • How to Surface Mount the SEL-735 Meter

                • How to Set SEL-735 Power Quality and Revenue Meter

                • How to Use SEL Easily Extractable Meters

                • SEL-735: Scaling in SEL Meters

                SEL-735 Visualize System Losses

                SEL-735 Meter Multifunction Display

                1 of 3
                • SEL-735 Visualize System Losses

                • How to Set the SEL-735 With Color Touchscreen Display-Basic Settings

                • How to Use SEL-735 With Color Touchscreen Display-Overview

                How to Use SEL-735 WAVE VIEW

                Meter Reporting and Analysis

                1 of 3
                • How to Use SEL-735 WAVE VIEW

                • How to Use acSELerator Meter Reports SEL-5630 Software

                • Customizing Reports in acSELerator Meter Reports Software

                How to Set the SEL-735 Meter With DNP Map Settings

                Meter Communication Settings

                1 of 2
                • How to Set the SEL-735 Meter With DNP Map Settings

                • Pend Oreille Upgrades Substation With Innovative SEL RTAC, Axion, and Cabling Solution

                How to Set Up SEL Synchrowave Notifications and Alarms

                Continuous Waveform Streaming and Virtual Metering With SEL-735

                1 of 3
                • How to Set Up SEL Synchrowave Notifications and Alarms

                • How to Enable Continuous Waveform Streaming From the SEL-735

                • SEL-735 and SEL Synchrowave Virtual Metering