Login
Products
Solutions
Engineering Services
Education
Support
Company
Product Selector
SEL-351S
Overview
Documentation
Support
Configure
SEL-351S
Toggle Dropdown
Overview
Documentation
Support
Configure
Documentation
Featured
Instruction Manual
SEL-351S Protection System
Data Sheet
SEL-351S Protection System
Flyer
SEL-351S Protection System
Literature
Documents sorted by newest first.
Include English Literature
Literature
Flyers
Featured
SEL-351S Protection System
Distribution Solutions
SEL-9220 Fiber-Optic Adapter for SEL-300 Series Relays
SEL-351 Legacy Family and SEL-351 Protection System Family Product Comparison
Complete IEC 61850 Product Family
Data Sheets
SEL-351S Protection System
Design Template Guides
Simple Overcurrent and Reclosing Application for the SEL-351S Protection System With SEL-FT50/SEL-FR12 Support
Related Material
SEL-5030 Database file - SEL-351S with SEL-FT50/SEL-FR12 Simple Overcurrent
Horizontal Labels - SEL-351S with SEL-FT50/SEL-FR12 Simple Overcurrent
Vertical Labels - SEL-351S with SEL-FT50/SEL-FR12 Simple Overcurrent
SEL-351S Protection System Two-Relay Main-Tie-Main Automatic Transfer Scheme Control Application
Related Material
SEL-5030 Database File - SEL-351S Two-Relay Main-Tie-Main
Horizontal Labels - SEL-351S Two-Relay Main-Tie-Main
Vertical Labels - SEL-351S Two-Relay Main-Tie-Main
Legacy SEL-351S Two-Relay Main-Tie-Main Automatic Transfer Scheme Control Application
Related Material
SEL-5030 Database File - Legacy SEL-351S Two-Relay Main-Tie-Main
Horizontal Labels - Legacy SEL-351S Two-Relay Main-Tie-Main
Vertical Labels - Legacy SEL-351S Two-Relay Main-Tie-Main
SEL-351S Three-Relay Main-Tie-Main Automatic Transfer Scheme Control Application
Related Material
SEL-5030 Database File - SEL-351S Three-Relay Main-Tie-Main
SEL-351S - R4xx Main Breaker Labels
SEL-351S - R4xx Tie Breaker Labels
SEL-351S - R5xx Main Breaker Labels
SEL-351S - R5xx Tie Breaker Labels
Simple Overcurrent and Reclosing Application for the SEL-351S Protection System
Related Material
SEL-5030 Database File - SEL-351S Simple Overcurrent
Horizontal Labels - SEL-351S Simple Overcurrent
Vertical Labels - SEL-351S Simple Overcurrent
SEL-351S Relay EZ Settings
Related Material
SEL-5030 Database File - SEL-351S EZ Settings
Label Template - SEL-351S EZ Settings
Guideform Specifications
SEL-351S Protection System
SEL-351S Protection System
Instruction Manuals
SEL-351S Protection System
Legacy SEL-351S
Settings Sheets
SEL-351S DNP Settings Sheets
SEL-351S Modbus Settings Sheets
SEL-351S Protection System Settings Sheets
Configurable Labels
SEL-311C-1, -2, SEL-351S Configurable Label Template (Horizontal)
SEL-311C-1, -2, SEL-351S Configurable Label Template (Horizontal; A4)
SEL-311C, SEL-351S Configurable Label Template (Vertical)
SEL-311C, SEL-351S Configurable Label Template (Vertical; A4)
SEL-351, SEL-351A, SEL-351S Configurable Label Instructions
Ordering Information
SEL-351S Model Option Table
Related Downloads
SEL-351S DNP3 Device Profile Information
Certificates
IEC 61850 Conformance and Interoperability Statement - SEL-351S Protection System
IEC 61850 KEMA Conformance Certificate - SEL-351S/A
Model Implementation Conformance Statement for the IEC 61850 interface in SEL-351, 351S, 351A
Protocol Implementation Conformance Statement for the IEC 61850 interface in SEL-351, 351S, 351A
Protocol Implementation eXtra Information for Testing (PIXIT) for the IEC 61850 interface in SEL-351, 351S, 351A
TISSUES Implementation Conformance Statement for the IEC 61850 interface in SEL-351, 351S, 351A
Publications
Application Guides
Modifying the Reclosing, Ground, and Hot-Line Tag Logic in the SEL-351S, SEL-451, and SEL-751 Relays
Maintaining Switched-Mode Relay Responsiveness in an RSTP Network
Testing Power Elements in the SEL-351S, SEL-421, and SEL-700G
Related Material
Testing Power Elements
Introduction to SEL Relays for New Users
Defining DCE and DTE: Null Modem Cable and Straight-Through Cable Applications
Testing Reclosing Sequence in SEL-300 Series Relays and SEL-700 Series Relays
Applying Second Harmonic Blocking in Distribution Relays
Understanding and Effectively Using the SEL
Mirrored Bits
Protocol
Setting and Testing Frequency Elements With Time Delay in Cycles
Using the SEL-FT50/SEL-FR12 System to Block Reclosing for Underground Trunk Faults
Using the SEL-FT50/SEL-FR12 System to Improve the Selectivity of Reclose Blocking for Feeder Exit Cables
Application Considerations When Applying SEL-351 Series Relays With Auxiliary Trip/Close Pushbuttons on AC Control Circuits
Revised Setting Guidelines for E32 in SEL Relays
Calculating and Testing the Operating Time of an Inverse-Time Overcurrent Curve
Related Material
Calculating 51 Operating Time
Phase Directional Overcurrent Settings Recommendations for Wind Farm Applications Using the SEL-351S
Enabling Instantaneous Tripping During a Hot Line Tag Condition With the SEL-351S, SEL-351R, and SEL-651R Relays
Enabling Sensitive Directional Tripping for Non-Line Protection Applications With SEL-351 Series Relays
Application Notes
Detect Transformer Inrush and Improve Protection Security on Feeders Using Second-Harmonic Blocking Logic in the SEL-351 and SEL-351S
Drawings