Produtos
Soluções
Engenharia e Serviços
Educação
Suporte
Empresa
Login
SEL-T400L
Visão geral
Documentos
Suporte
SEL-T400L
Toggle Dropdown
Visão geral
Documentos
Suporte
Documentos
Em destaque
Manual de instruções
SEL-T400L Time Domain Line Protection
Data Sheet
SEL-T400L Time-Domain Line Protection
Flyer
SEL-T400L - Proteção de Linhas de Transmissão no Domínio do Tempo
Literatura
Os documentos são classificados pela mais nova primeiro.
Incluir Literatura em Inglês
Literatura
Flyers
SEL-T400L - Proteção de Linhas de Transmissão no Domínio do Tempo
Data Sheets
Inglês
SEL-T400L Time-Domain Line Protection
Guias de especificação
Inglês
SEL-T400L Time-Domain Line Protection
SEL-T400L Time-Domain Line Protection
Manuais de instruções
Inglês
SEL-T400L Time Domain Line Protection
Etiquetas configuráveis
Inglês
SEL-T400L Custom Label Instructions
Related Material
SEL-T400L, SEL-T401L, and SEL-TWFL Custom Label Template (Letter)
SEL-T400L, SEL-T401L, and SEL-TWFL Custom Label Template (A4)
Downloads relacionados
Inglês
SEL-T400L DNP Device Profile Information
Publicações
Guias de aplicação
Inglês
Double-Ended Traveling-Wave Fault Locating Using the SEL RTAC as a DNP3 Client
Related Material
fb_TWFaultLocation.xml
Using an SEL RTAC to Integrate the SEL-T400L Relay With SCADA
Artigos técnicos
Localização Rápida de Faltas Poupa Recursos e Melhora a Qualidade do Serviço
Prevenção de Faltas em Linhas de Transmissão com Monitoramento Contínuo Baseado em Ondas Viajantes
Aplicação de Proteção de Ultra Alta Velocidade e Localização de Faltas por Ondas Viajantes em uma Linha Híbrida
Experiência em Campo Com um Relé de Linhas de Transmissão de Ultra-Alta-Velocidade e Localizador de Faltas por Ondas Viajantes
Inglês
Case Study: Traveling-Wave Fault Locating for an HVdc Transmission Line
Dependability of Transient-Based Line Protection Elements and Schemes
Energy and Power Measurements on a Nonsinusoidal 345 kV System Using Three-Phase Megahertz Time-Series Data
Megahertz-Sampled Observations of AC Level 2 Onboard Electric Vehicle Charging
Getting the Lines Crossed—How a Three-Phase Series Fault Caused a Sequence of Relay Operations
Evaluating Phasor-Based and Time-Domain Elements for Short Line Applications
Correlating Traveling-Wave Arrival Times to the Bewley Diagram—A New Systematic Approach for Offline Traveling-Wave Fault Locating
UHS Relay Testing for Optimal Protection of a Long 345 kV Line With Series Compensation
An Unlikely Pair? Combining Traveling Waves and Phasors for Reclosing on Hybrid Lines
A Method for Evaluating Loadability of Incremental-Quantity Distance Elements
Evaluation of Ultra-High-Speed Line Protection, Traveling-Wave Fault Locating, and Circuit Breaker Reignition Detection on a 220 kV Line in the Kalahari Basin, Namibia
Traveling-Wave Overcurrent – A New Way to Protect Lines Terminated on Transformers
Double-Ended Traveling-Wave Fault Locating Without Relay-to-Relay Communications
Distance Protection: Why Have We Started With a Circle, Does It Matter, and What Else Is Out There?
Line Length and Fault Distance Considerations in Traveling-Wave Protection and Fault-Locating Applications
Circuit Breaker Ratings – A Primer for Protection Engineers
Locating Faults Before the Breaker Opens – Adaptive Autoreclosing Based on the Location of the Fault
Improving Line Crew Dispatch Accuracy When Using Traveling-Wave Fault Locators
Practical Experience With Ultra-High-Speed Line Protective Relays
Mystery Solved: Five Surprises Discovered With Megahertz Sampling and Traveling-Wave Data Analysis
Traveling-Wave Fault Locating for Multiterminal and Hybrid Transmission Lines
Testing Traveling-Wave Line Protection and Fault Locators
Testing Superimposed-Component and Traveling-Wave Line Protection
Accurate and Economical Traveling-Wave Fault Locating Without Communications
Sharing Direct Fiber Channels Between Protection and Enterprise Applications Using Wavelength Division Multiplexing
Directional Elements – How Fast Can They Be?
Performance Comparison Between Mho Elements and Incremental Quantity-Based Distance Elements
Practical Setting Considerations for Protective Relays That Use Incremental Quantities and Traveling Waves
Defining and Measuring the Performance of Line Protective Relays
Performance of Time-Domain Line Protection Elements on Real-World Faults
Speed of Line Protection – Can We Break Free of Phasor Limitations?
Locating Faults by the Traveling Waves They Launch
Desenhos
AutoCAD
Inglês
i6353e Rear View
i9340d Dimensional View
i6352f Front View
PDF
Inglês
i6352f Front View
i6353e Rear View
i9340d Dimensional View