Security Notifications
Issues Reported by External Organizations or Individuals
Vulnerabilities are disclosed to SEL customers in three ways:
- For high-risk vulnerabilities—through a Service Bulletin
- For other vulnerabilities—through a revision to Appendix A of the affected product’s instruction manual
- For software products—through an addition to the Latest Software Versions page on the SEL website
After our private customer notification process is complete, we publish information about vulnerabilities reported to SEL as Security Notifications.
CVE ID | Acknowledgement | Description |
---|---|---|
CVE-2023-34391 | Reid Wightman of Dragos | Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 acSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details. This issue affects SEL-5033 acSELerator RTAC Software: before 1.35.151.21000. |
CVE-2023-34392 | Andrea Palanca and Gabriele Quagliarella of Nozomi Networks | A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. |
CVE-2023-31167 | Reid Wightman of Dragos | Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal. SEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details. This issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778. |
CVE-2023-31168 | Gabriele Quagliarella of Nozomi Networks | An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. |
CVE-2023-31169 | Gabriele Quagliarella of Nozomi Networks | An Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. |
CVE-2023-31170 | Gabriele Quagliarella of Nozomi Networks | An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. |
CVE-2023-31171 | Gabriele Quagliarella of Nozomi Networks | An Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. |
CVE-2023-31172 | Andrea Palanca and Gabriele Quagliarella of Nozomi Networks | An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. |
CVE-2023-31173 | Gabriele Quagliarella of Nozomi Networks | Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. |
CVE-2023-31174 | Andrea Palanca of Nozomi Networks | A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. |
CVE-2023-31175 | Andrea Palanca of Nozomi Networks | An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. |
CVE-2023-2310 | Adeen Ayub, Syed Ali Qasim, Irfan Ahmed, Virginia Commonwealth University | A Channel Accessible by Non-Endpoint vulnerability in the Schweitzer Engineering Laboratories SEL Real-Time Automation Controller (RTAC) could allow a remote attacker to perform a man-in-the-middle (MiTM) that could result in denial of service. See the acSELerator RTAC SEL-5033 Software instruction manual date code 20210915 for more details. |
CVE-2023-31148 | Andrea Palanca, Nozomi Networks | An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to execute arbitrary code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31149 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31150 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31151 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31152 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31153 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31154 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31155 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31156 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31157 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31158 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31159 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31160 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31161 | Andrea Palanca, Nozomi Networks | "An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow an authenticated remote attacker to use internal resources, allowing a variety of potential effects. See SEL Service Bulletin dated 2022-11-15 for more details." |
CVE-2023-31162 | Andrea Palanca, Nozomi Networks | An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to arbitrarily alter the content of a configuration file. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31163 | Andrea Palanca, Nozomi Networks | An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to arbitrarily alter the content of a configuration file. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31164 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31165 | Andrea Palanca, Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31166 | Andrea Palanca, Nozomi Networks | An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system. See SEL Service Bulletin dated 2022-11-15 for more details. |
CVE-2023-31176 | Andrea Palanca and Gabriele Quagliarella of Nozomi Networks | An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication. See product Instruction Manual Appendix A dated 20230830 for more details. |
CVE-2023-31177 | Andrea Palanca and Gabriele Quagliarella of Nozomi Networks | An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim's system. See product Instruction Manual Appendix A dated 20230830 for more details. |
CVE-2023-34388 | Andrea Palanca and Gabriele Quagliarella of Nozomi Networks | An Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication. See product Instruction Manual Appendix A dated 20230830 for more details. |
CVE-2023-34389 | Andrea Palanca and Gabriele Quagliarella of Nozomi Networks | An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time. See product Instruction Manual Appendix A dated 20230830 for more details. |
CVE-2023-34390 | Andrea Palanca and Gabriele Quagliarella of Nozomi Networks | An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services. See product Instruction Manual Appendix A dated 20230830 for more details. |
CVE-2023-2264 | Sushant Mane, Parul Sindhwad, Imran Jamadar & Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai, India. | An improper input validation vulnerability in the Schweitzer Engineering Laboratories SEL-411L could allow a malicious actor to manipulate authorized users to click on a link that could allow undesired behavior. See product Instruction Manual Appendix A dated 20230830 for more details. |
CVE-2023-2265 | Sushant Mane, Parul Sindhwad, Imran Jamadar & Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai, India. | An Improper Restriction of Rendered UI Layers or Frames in the Schweitzer Engineering Laboratories SEL-411L could allow an unauthenticated attacker to perform clickjacking based attacks against an authenticated and authorized user. See product Instruction Manual Appendix A dated 20230830 for more details. |
CVE-2023-2266 | Sushant Mane, Parul Sindhwad, Imran Jamadar & Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai, India. | An Improper neutralization of input during web page generation in the Schweitzer Engineering Laboratories SEL-411L could allow an attacker to generate cross-site scripting based attacks against an authorized and authenticated user. See product Instruction Manual Appendix A dated 20230830 for more details. |
CVE-2023-2267 | Sushant Mane, Parul Sindhwad, Imran Jamadar & Dr. Faruk Kazi from CoE-CNDS Lab, VJTI, Mumbai, India. | An Improper Input Validation vulnerability in Schweitzer Engineering Laboratories SEL-411L could allow an attacker to perform reflection attacks against an authorized and authenticated user. See product Instruction Manual Appendix A dated 20230830 for more details. |
CVE-2024-2103 | Anonymous researcher |
Inclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably.
See product instruction manual appendix A dated 20240308 for more details regarding the SEL-751 Feeder Protection Relay. For more information for the other affected products, see their instruction manuals dated 20240329. |
Please note, this notification listing is not a complete record of all product vulnerability disclosures or cybersecurity feature enhancements and includes only issues reported to SEL by external organizations or individuals.